BASIC WEIGHING AND TOTALIZING
Static Weighing Method

COMPULOAD 3000 Series
Version CL3V1.16  Mod 11/05/.2004


2 Static Weighing Method
NOTE 1
All  reference  to  weighing  position  refers to raising  the  bucket   fully crowded up to a pre- determined  position  and  lowering  slightly and slowly.

The pre-determined  position  may  be  determined by either a pointer    or having  the  lift  detent cut-out set at a given position.

NOTE 2
When first turned on and sometimes through the operation a message will appear showing  “Zero Required”  In this instance proceed as in 2a below

2.a With the bucket empty, raise up to the weighing position.
 (If other than 0.00 (zero) is displayed press  ZERO  key for two seconds.
2.b  Apply the load and raise up to the weighing position. (the weight will be displayed on the top line of the display)
2.c  Press LOAD to add weight into the 'total' display.
NOTE 3
For further weighings carry out steps 2.b & c

NOTE 4
By pressing FUNC then LOAD twice allows operator to enter target weight to load  onto truck. Compuload will show "enter alarm weight"

Use UP/DOWN keys to enter truck capacity.
0.00 turns target weight alarm off
Press LOAD to save setting