OPERATING INSTRUCTIONS
BASIC WEIGHING
AND TOTALIZING
Static Weighing Method
COMPULOAD 3000 Series
Version CL3V1.16 Mod 11/05/.2004
2 | Static Weighing Method |
NOTE 1
All reference to weighing position refers to raising the bucket fully crowded up to a pre- determined position and lowering slightly and slowly.The pre-determined position may be determined by either a pointer or having the lift detent cut-out set at a given position.
NOTE 2
When first turned on and sometimes through the operation a message will appear showing “Zero Required” In this instance proceed as in 2a below
2.a | With the bucket empty, raise up to the weighing
position.
(If other than 0.00 (zero) is displayed press ZERO key for two seconds. |
2.b | Apply the load and raise up to the weighing position. (the weight will be displayed on the top line of the display) |
2.c | Press LOAD to add weight into the 'total' display. |
NOTE 3
For further weighings carry out steps 2.b & cNOTE 4
By pressing FUNC then LOAD twice allows operator to enter target weight to load onto truck. Compuload will show "enter alarm weight"Use UP/DOWN keys to enter truck capacity.
0.00 turns target weight alarm off
Press LOAD to save setting
Click here for other Key Options:
Top of Page |