OPERATING INSTRUCTIONS
COMPULOAD 3000 Series
LOAD
WEIGHING SYSTEM
Version CL3V1.16 Mod 11/05/.2004
BASIC WEIGHING AND TOTALIZING
Dynamic Weighing Method
Lift Speed Compensated as Load is Raised
1 | Dynamic Weighing Method: |
1.a | With the bucket empty and fully crowded raise up through the lift sensor switch at a smooth steady lifting speed. If other than 0.00 (zero) is displayed press ZERO for two seconds to zero display. |
1.b | Apply the load and raise up through the lift sensor switch at a smooth steady lifting speed. Display will show "weighing", then the weight will be displayed for a pre-determined period (usually 8 seconds) |
1.c | Press LOAD to add weight into the 'total' display. |
1.d | Press CLEAR for two seconds when required total is reached. This returns TOTAL display to 0.00 ready for the next truck. |
This function allows the sensor to preform tasks as follows.
a | HOLD & ADD Weight is "held" on display for a
pre-determined period.
Weight is automatically added into the TOTAL display. |
b | HOLDS ONLY Weight is "held" on display for a
pre-determined period.
Weight can be added into TOTAL display with LOAD key. |
c | DOES NOTHING
No action from lift sensor. |
Use UP/DOWN keys to scroll through options.
Press LOAD to save selection. |
After LOAD is pressed when trigger task is selected an
option allows
the operator to enter target weight to load onto truck.
COMPULOAD will show “enter alarm weight" |
|
Use UP/DOWN keys to enter the truck capacity.
“0.00” turns target weight alarm off . Press LOAD to save setting the CLEAR for two seconds to exit |
I) | Lift the load at a smooth speed through the lift
sensor.
Do not stop the lift cycle until a weight reading is obtained |
II) | Open lifting valve fully to raise the load |
III) | When weighing have loader on a level surface |
III) | Avoid excessive bounce on rough surfaces while weighing. |
IV) | Regularly check the zero. (Step 1) |
Top of Page |